TU 4211-030-00225590-99
Thermometers manometrical showing signaling Tm2030sg-1 (with gas filler) and Tm2030sg-2 (with condensation filler) are intended for continuous measurement of temperature of liquids and gases, neutral concerning their impact on steel and copper alloys, and managements of external electric chains from the signaling device. Are applied in various installations and in systems of heat power control where timely information on the reached extreme values of temperature is necessary.
For elimination of influence of a tinkling sound, a podgoraniye and oxidation on operation of the signaling device devices can be delivered in a complete set with URK.
Main technical characteristics
- Ranges of indications of devices:
- Tm2030sg-1 - from-50 to 50; 100; 150 °C
- Tm2030sg-1 - from 0 to 150; 160; 200; 300; 400; °C
- Tm2030sg-1 - from 100 to 300; 500 °C
- Tm2030sg-1 - from 200 to 500 °C
- Tm2030sg-2 - from-25 to 75 °C
- Tm2030sg-2 - from 0 to 60; 100 °C
- Tm2030sg-2 - from 100 to 200; 250 °C
- Diameter of the case - 100 mm
- Class of accuracy of devices - 2,5
- Degree of protection - IP53
- The mass of devices with a length of capillary of 1 meter - no more than 1,5 kg
- Average service life - 10 years
- Materials of details:
- the case - steel, an aluminum alloy
- glass - cast organic
- thermocylinder - Tm2030sg-1 - stainless steel; Tm2030sg-2 - a copper alloy
- On resistance to climatic influences devices have execution of U2 in accordance with GOST 15150-69 (but for work at a temperature for Tm2030sg-1 - from minus 10 to plus 60 °C, for Tm2030sg-2 - from minus 50 to plus 60 °C)
- Devices maintain impact of vibration in the range of frequencies from 5 to 35 Hz with an amplitude of 0,35 mm (L1 group in accordance with GOST P 52931-2008)
- Diameter of a thermocylinder:
- Tm2030sg-1 - 20 mm, a carving of the union (D1) - М33×2-8g
- Tm2030sg-2 - 14 mm, a carving of the union (D1) - М27×2-8g
- Length of a connecting capillary (L)
- 1,6m; 2,5m; 4 m; 6 m; 10 m - by request
- Length of the immersed part (L1)
- Tm2030sg-1 - according to table 1
- TM 2030sg-2 - 125 mm; 160 mm; 200 mm;
Table 1
Range of measurements, ° C
|
L, m
|
L1, m
|
to 300
|
from 1 to 6
|
160; 200; 250
|
from 1 to 10
|
315; 400; 500
|
from 0 to 400
|
from 1 to 10
|
315
|
from +100 to 500
|
from +200 to 500
|
- Technological line on a scale
- -//- by default without line
- "line" - by request causing technological line on the dial (to the order surely specify in the note on what mark)
Parameters of the signaling device for the signaling manometers
- The signaling device on connection of external chains has four options of execution in accordance with GOST 2405-88:
- -//- by default V - the left contact disconnecting (min), right closing (max) – both indexes blue.
- III - two disconnecting contacts: the left index (min) - blue, right (max) - red.
- IV - two closing contacts: the left index (min) - red, right (max) - blue.
- VI - the left contact closing (min), right disconnecting (max) – both indexes red.
- MT - By request of the consumer the signaling device can be produced with magnetic preload of contacts for any of above the specified executions.
- Tension of the external switched chains:
- 380 V (including 24; 27; 36; 40; 110; 220B) - for chains of alternating current;
- 220 V (including 24; 27; 36; 40; 110B) - for chains of a direct current
- Explosive power of contacts for the signaling device:
- with the sliding contacts – 10 W of a direct current and 20 V • And alternating current;
- with magnetic preload of contacts – 30 W of a direct current and 50 V • And alternating current
- Value of the switched current:
- for the signaling device with the sliding contacts – from 0,02 to 0,5 And;
- for the signaling device with magnetic preload of contacts – from 0,01 to 1 And
- Limit of the allowed main error of operation of the signaling device:
- for the signaling device with the sliding contacts of ±2,5%
- for the signaling device with magnetic preload of contacts of ±4%
- Connection is carried out by a four-vein cable, with a section of veins from 0,2 to 1,5 mm2. Diameter of input in the socket - from 4 to 10 mm.
- Scheme of connection
|